Evaporators with heat pump and internal scraper for encrusting liquids. Heating coils are
attached to the outside of the boiler and the internal scraper is used to
keep the inside of the boiler free of dried material.
Vacuum operating with Venturi jet pump. Heating shell which forms an single
block with the boiler. Also available is the S Series water evaporator
with a Serpentine condenser inside the boiler. Heat pump
is R22/R407C compatible.
Download PDF file
|
technical
characteristic |
unit
of
measur. |
WT 15
HPR |
WT 20
HPR |
WT 30
HPR |
WT 50
HPR |
WT 60
HPR |
|
Production* |
kg/h |
15 |
25 |
35 |
50 |
60 |
|
Installed power |
kW |
4,0 |
5,0 |
7,0 |
12,0 |
14,0 |
|
Absorbed power* |
kW |
2,8 |
4,2 |
6,5 |
9,2 |
11,2 |
|
Specific consumption |
kWh/l |
0,18 |
0,18 |
0,18
|
0,18 |
0,18 |
|
Frequency |
Hz |
50 |
50 |
50 |
50 |
50 |
|
Voltage |
V |
380 |
380 |
380 |
380 |
380 |
|
Material in contact |
|
AISI
304** |
AISI
304** |
AISI
304** |
AISI
304** |
AISI
304** |
|
Automatic unloading -
distillate |
|
l |
l |
l |
l |
l |
|
Autom. Unloading - residue |
|
¡ |
¡ |
¡ |
¡ |
¡ |
|
Programming process control
|
|
l |
l |
l |
l |
l |
|
pH control |
|
¡ |
¡ |
¡ |
¡ |
¡ |
|
Dimensions |
cm |
133x96x225 |
133x96x225 |
133x96x245 |
172x125x232 |
172x125x232 |
|
weight |
kg |
350 |
470 |
520 |
750 |
790 |
l
Standard
¡ Optional
** Available also in special materials
*
the production and the absorbed
power refer to watery solutions with specific weight 1 kg/dm3 fed
at 25°C with total evaporation heating of 600 kcal/kg with heating pumps
filled with freon R22.
|